| Contact Us | Worldwide Contacts | Home
회사소개 사업부문 고객상담실 Investors
사업부문
Overview
Orthopaedics
Endoscopy
> Wound Management
  제품소개
     Chronic Wound Care
       Allevyn Standard
       Allevyn Adhesive
       Allevyn Cavity
       Allevyn heel
       Allevyn Sacrum
       Allevyn Thin
       Acticoat
       Cutinova Hydro
       Replicare Ultra
       IntraSite Gel
       Intrasite Conformable
       Algisite* M
       OpSite Flexifix
       OpSite* Flexigrid
     Acute Wound Care
       OpSite Post-OP
       OpSite Incise Drapes
       IV 3000
    Scar Therapy
       Cica-Care
  Education
  FAQ
  새소식
  Medical Term Glossary
Email this page



아이브이 3000은 1 Hand 습기반응식 카테터 고정용 드레싱

IV3000은 습기반응식이며 카테터 고정을 위해 특별히 고안된 드레싱으로 카테터 고정 부분을 건조하게 잘 유지 시켜줍니다.
임상실험에 따르면 IV3000은 감염으로 부터 안전하고 지속적인 사용이 가능하기 때문에 비용절감에도 효과적인 제품입니다.
1 Hand delivery system 으로 빠르고 쉽게 적용할 수 있는 편리한 제품입니다.

제품 특성

  • 습기반응식의 높은 수분 증발률을 지닌 필름
  • 접착성의 격자무늬 패턴
  • 투명하고 유연한 필름
  • 1 hand delivery 시스템

제품 장점

Reduces risk of infection by preventing moisture accumulation
IV 3000은 특허받은 Reactic* 필름으로 일반적인 필름보다 수분 증발률이 높은 독특한 분자구조로 되어 있습니다. 드레싱과 피부 사이의 습기의 축적을 막아 박테리아의 증식을 막아주고 카테터로 인한 감염의 위험을 현저히 줄여줍니다.

Minimises unscheduled dressing changes
IV3000은 높은 수분 증발률로 카테터 부위의 피부를 건조하게 유지시켜주어 접착력을 오래 유지시켜주므로 불필요한 드레싱 교환횟수를 줄여줍니다.

Greater patient comfort
IV 3000의 필름은 알러지가 최소화 되고 피부가 진무르거나 자극받는 것을 막아 환자를 편안하게 해줍니다.

Excellent catheter stability
유연성이 높은 필름으로 환자의 움직임을 자유롭게 해주고 접착력이 높아 카테터를 확실하게 고정 시켜줍니다.

Convenient visual inspection
투명한 필름으로 드레싱을 제거하지 않고 유관으로 감염여부를 확인할 수 있습니다.

Waterproof barrier
방수기능으로 환자가 자유롭게 샤워할 수 있습니다.

Easy application and removal
1 hand delivery 시스템으로 적용이 매우 편리합니다.

적응증

카테터 고정용(Peripheral & central)

반적응증/ 주의사항

  • 카테터 고정 전용
  • 피부 건조 후 적용

Product Availability
Code
Size
Q'ty /Carton
4007
6cm x 7 cm
100개
4008
10cm x 12cm
50개
4654
5cm x 6cm
100개

사용법

피부를 청결히 하고 건조하게 유지합니다

Step 1:
이면지를 제거합니다. 드레싱을 카테터 삽입부위 상부 중앙에 위치시킵니다.







Step 2:
카테터 허브에 위치시키고 드레싱을 환자 피부에 부착시킵니다.
남아있는 보호지를 제거합니다.







Step 3:
접착 성분이 없는 가장자리를 들어올려 이면지를 제거될 때 까지 비스듬히 밀어내면서 인쇄된 이면지를 제거합니다.







Step 4:
드레싱 적용을 완벽하게 하기위해서 카테터 주변의 필름을 눌러줍니다.







Step 5:
필름을 늘이면서 환자 피부의 손상을 막기위해 다른 한 손으로 카테터를 잡으면서 피부 수평방향으로 늘이면서 드레싱을 제거합니다.
피부가 연약한 경우 연성비누나 피부가 접착성분을 제거하면 쉽게 드레싱을 제거할 수 있습니다.
금기사항과 주의사항은 제품 설명페이지를 참고해 주시기 바랍니다.

임상자료

Paper title:
Infection caused by intravascular devices: Pathogenesis, strategies for prevention

Author:
D.G. Maki

Reference:
In: International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society of Medicine Series, London, New York 1991; 179-3-27

Paper title:
The impact of dressing materials on central venous catheter infection rates.

Author:
J. Treston Aurand, R N Olmsted, K Allen-Bridson and C P Craig

Reference:
J. Intraven. Nurs, 1997; 20: 201-206

Paper title:
Improved catheter care for ITU patients.

Author:
Grandi A, Cigarini, R Chiesi and S Wertzberger.

Reference:
Poster presented at the 7th European Conference on Advances in Wound Management, Milan 1997.

Paper title:
Improved catheter care in the treatment of patients with colon carcinoma. The use of OpSite* IV3000* film dressing in conjunction with continuous infusion of Topotecan.

Author:
M de Boer, A Andriessen and D den Hoed.

Reference:
6th European Conference or Advances in Wound Management proceedings, Amsterdam, Holland. 1996: abstract 276.

Paper title:
OpSite IV3000 dressing on Permcath exit sites.

Author:
C Latta and C Grant

Reference:
EDTNA-ERCA. 1996; XXII: 7-8

Paper title:
Evaluation of OpSite IV3000 versus tape and gauze dressings in the management of central venous catheters in oncology patients.

Author:
E Berggren, L Bernell and R Hast.

Reference:
5th European Conference on Advances in Wound Management proceedings, Harrogate, UK. 1995; abstract 291

Paper title:
A randomised dressing method for haemodialysis patients with permanent central venous catheters.

Author:
M Hagerstrom, K Matthleson and C Thuessen

Reference:
4th European Conference on Advances in Wound Management proceedings, Copenhagen, Denmark. 1994; abstract 197

Paper title:
A prospective randomised trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management.

Author:
D G Maki, S Stolz, S Wheeler and L Mermel

Reference:
Critical Care Medicine. 1994; 22: 1729-1737

Paper title:
Avoiding an unnecessary outcome. A comparative trial betweenOpSite IV3000 and a conventional film dressing to assess rates of catheter related sepsis.

Author:
D Keenlyside

Reference:
Professional Nurse, February 1993; 228-29

Paper title:
A comparison of two transparent film type dressings in central venous therapy.

Author:
J C Wille, A Blusse van Oud Alblas and E A P M Theweesen

Reference:
J Hospital Infection. 1993; 23: 113-121

Paper title:
A clinical evaluation of a new highly permeable film dressing OpSite IV3000, for the fixation of peripheral and central venous catheters in neonates.

Author:
A Andriessen
Reference:
University Hospital of Nijmegen AZN, Netherlands (1991). Personal Communication.

Paper title:
A prospective, randomised, three-way clinical comparison of a novel highly permeable, polyurethane dressing with 206 Swan Ganz pulmonary artery catheters: OpSite IV3000 vs. Tegaderm vs gauze and tape. ii) Nursing issues : effectiveness and tolerance as catheter dressing.

Author:
S Wheeler, S Stolz and D G Maki

Reference:
International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society and Medicine Series, London, New York 1991; 179: 67-71

Paper title:
The research and development of a new transparent film dressing for intravenous catheter care, ii) An in vivo assessment of the microbial proliferation beneath transparent film dressings.

Author:
M C Richardson
Reference:
International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 29-33

Paper title:
OpSite IV3000 ?a clinical evaluation of a new transparent film dressing for central venous catheters.

Author:
K Claeys and D Degrieck

Reference:
International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 35-40

Paper title:
OpSite IV3000 ?potential for improved quality of life for haemodialysis patients with permanent central venous catheters.

Author:
M Besley
Reference:
International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 57-59

Paper title:
OpSite IV3000 ?versus Tegaderm on peripheral venous catheters.

Author:
B Joyeux
Reference:
International Congress and Symposium Series, 멗mproving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 53-55

Paper title:
A randomised controlled trial of the effectiveness of OpSite* Wound versus OpSite IV3000 in central line fixation.

Author:
M Neufeld
Reference:
MSc thesis, McMaster University, Canada 1991

Paper title:
Triple Lumen Study ?Abstract

Author:
D G Maki
Reference:
University of Wisconsin Hospital and Clinic, USA (1990). Clinical study. Data on file.


Copyright & disclaimer © 2002 Smith & Nephew