¾ÆÀ̺êÀÌ 3000Àº 1 Hand ½À±â¹ÝÀÀ½Ä Ä«Å×ÅÍ °íÁ¤¿ë µå·¹½Ì
IV3000Àº ½À±â¹ÝÀÀ½ÄÀ̸ç Ä«Å×ÅÍ °íÁ¤À» À§ÇØ Æ¯º°È÷ °í¾ÈµÈ µå·¹½ÌÀ¸·Î Ä«Å×ÅÍ °íÁ¤ ºÎºÐÀ» °ÇÁ¶ÇÏ°Ô Àß À¯Áö ½ÃÄÑÁÝ´Ï´Ù.
ÀÓ»ó½ÇÇè¿¡ µû¸£¸é IV3000Àº °¨¿°À¸·Î ºÎÅÍ ¾ÈÀüÇÏ°í Áö¼ÓÀûÀÎ »ç¿ëÀÌ °¡´ÉÇϱ⠶§¹®¿¡ ºñ¿ëÀý°¨¿¡µµ È¿°úÀûÀÎ Á¦Ç°ÀÔ´Ï´Ù.
1 Hand delivery system À¸·Î ºü¸£°í ½±°Ô Àû¿ëÇÒ ¼ö ÀÖ´Â Æí¸®ÇÑ Á¦Ç°ÀÔ´Ï´Ù.
Á¦Ç° Ư¼º
-
½À±â¹ÝÀÀ½ÄÀÇ ³ôÀº ¼öºÐ Áõ¹ß·üÀ» Áö´Ñ Çʸ§
-
Á¢Âø¼ºÀÇ °ÝÀÚ¹«´Ì ÆÐÅÏ
-
Åõ¸íÇÏ°í À¯¿¬ÇÑ Çʸ§
-
1 hand delivery ½Ã½ºÅÛ
Á¦Ç° ÀåÁ¡
Reduces risk of infection by preventing moisture accumulation
IV 3000Àº ƯÇã¹ÞÀº Reactic* Çʸ§À¸·Î ÀϹÝÀûÀÎ Çʸ§º¸´Ù ¼öºÐ Áõ¹ß·üÀÌ ³ôÀº µ¶Æ¯ÇÑ ºÐÀÚ±¸Á¶·Î µÇ¾î ÀÖ½À´Ï´Ù. µå·¹½Ì°ú
ÇǺΠ»çÀÌÀÇ ½À±âÀÇ ÃàÀûÀ» ¸·¾Æ ¹ÚÅ׸®¾ÆÀÇ Áõ½ÄÀ» ¸·¾ÆÁÖ°í Ä«Å×ÅÍ·Î ÀÎÇÑ °¨¿°ÀÇ À§ÇèÀ» ÇöÀúÈ÷ ÁÙ¿©ÁÝ´Ï´Ù.
Minimises unscheduled dressing changes
IV3000Àº ³ôÀº ¼öºÐ Áõ¹ß·ü·Î Ä«Å×ÅÍ ºÎÀ§ÀÇ ÇǺθ¦ °ÇÁ¶ÇÏ°Ô À¯Áö½ÃÄÑÁÖ¾î Á¢Âø·ÂÀ» ¿À·¡ À¯Áö½ÃÄÑÁֹǷΠºÒÇÊ¿äÇÑ µå·¹½Ì ±³È¯È½¼ö¸¦
ÁÙ¿©ÁÝ´Ï´Ù.
Greater patient comfort
IV 3000ÀÇ Çʸ§Àº ¾Ë·¯Áö°¡ ÃÖ¼ÒÈ µÇ°í ÇǺΰ¡ Áø¹«¸£°Å³ª Àڱع޴ °ÍÀ» ¸·¾Æ ȯÀÚ¸¦ Æí¾ÈÇÏ°Ô ÇØÁÝ´Ï´Ù.
Excellent catheter stability
À¯¿¬¼ºÀÌ ³ôÀº Çʸ§À¸·Î ȯÀÚÀÇ ¿òÁ÷ÀÓÀ» ÀÚÀ¯·Ó°Ô ÇØÁÖ°í Á¢Âø·ÂÀÌ ³ô¾Æ Ä«Å×Å͸¦ È®½ÇÇÏ°Ô °íÁ¤ ½ÃÄÑÁÝ´Ï´Ù.
Convenient visual inspection
Åõ¸íÇÑ Çʸ§À¸·Î µå·¹½ÌÀ» Á¦°ÅÇÏÁö ¾Ê°í À¯°üÀ¸·Î °¨¿°¿©ºÎ¸¦ È®ÀÎÇÒ ¼ö ÀÖ½À´Ï´Ù.
Waterproof barrier
¹æ¼ö±â´ÉÀ¸·Î ȯÀÚ°¡ ÀÚÀ¯·Ó°Ô »þ¿öÇÒ ¼ö ÀÖ½À´Ï´Ù.
Easy application and removal
1 hand delivery ½Ã½ºÅÛÀ¸·Î Àû¿ëÀÌ ¸Å¿ì Æí¸®ÇÕ´Ï´Ù.
ÀûÀÀÁõ
Ä«Å×ÅÍ °íÁ¤¿ë(Peripheral & central)
¹ÝÀûÀÀÁõ/ ÁÖÀÇ»çÇ×
-
Ä«Å×ÅÍ °íÁ¤ Àü¿ë
-
ÇǺΠ°ÇÁ¶ ÈÄ Àû¿ë
Product Availability
Code
|
Size
|
Q'ty /Carton
|
4007
|
6cm x 7 cm
|
100°³
|
4008
|
10cm x 12cm
|
50°³
|
4654
|
5cm x 6cm
|
100°³
|
|
»ç¿ë¹ý
ÇǺθ¦ û°áÈ÷ ÇÏ°í °ÇÁ¶ÇÏ°Ô À¯ÁöÇÕ´Ï´Ù
Step 1:
À̸éÁö¸¦ Á¦°ÅÇÕ´Ï´Ù. µå·¹½ÌÀ» Ä«Å×ÅÍ »ðÀÔºÎÀ§ »óºÎ Áß¾Ó¿¡ À§Ä¡½Ãŵ´Ï´Ù.
Step 2:
Ä«Å×ÅÍ Çãºê¿¡ À§Ä¡½ÃÅ°°í µå·¹½ÌÀ» ȯÀÚ ÇǺο¡ ºÎÂø½Ãŵ´Ï´Ù.
³²¾ÆÀÖ´Â º¸È£Áö¸¦ Á¦°ÅÇÕ´Ï´Ù.
Step 3:
Á¢Âø ¼ººÐÀÌ ¾ø´Â °¡ÀåÀÚ¸®¸¦ µé¾î¿Ã·Á À̸éÁö¸¦ Á¦°ÅµÉ ¶§ ±îÁö ºñ½ºµëÈ÷ ¹Ð¾î³»¸é¼ ÀμâµÈ À̸éÁö¸¦ Á¦°ÅÇÕ´Ï´Ù.
Step 4:
µå·¹½Ì Àû¿ëÀ» ¿Ïº®ÇÏ°Ô ÇϱâÀ§Çؼ Ä«Å×ÅÍ ÁÖº¯ÀÇ Çʸ§À» ´·¯ÁÝ´Ï´Ù.
Step 5:
Çʸ§À» ´ÃÀÌ¸é¼ È¯ÀÚ ÇǺÎÀÇ ¼Õ»óÀ» ¸·±âÀ§ÇØ ´Ù¸¥ ÇÑ ¼ÕÀ¸·Î Ä«Å×Å͸¦ ÀâÀ¸¸é¼ ÇǺΠ¼öÆò¹æÇâÀ¸·Î ´ÃÀÌ¸é¼ µå·¹½ÌÀ» Á¦°ÅÇÕ´Ï´Ù.
ÇǺΰ¡ ¿¬¾àÇÑ °æ¿ì ¿¬¼ººñ´©³ª ÇǺΰ¡ Á¢Âø¼ººÐÀ» Á¦°ÅÇÏ¸é ½±°Ô µå·¹½ÌÀ» Á¦°ÅÇÒ ¼ö ÀÖ½À´Ï´Ù.
±Ý±â»çÇ×°ú ÁÖÀÇ»çÇ×Àº Á¦Ç° ¼³¸íÆäÀÌÁö¸¦ Âü°íÇØ Áֽñ⠹ٶø´Ï´Ù.
ÀÓ»óÀÚ·á
Paper title:
Infection caused by intravascular devices: Pathogenesis, strategies for prevention
Author:
D.G. Maki
Reference:
In: International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society of Medicine Series, London, New York 1991; 179-3-27
Paper title:
The impact of dressing materials on central venous catheter infection rates.
Author:
J. Treston Aurand, R N Olmsted, K Allen-Bridson and C P Craig
Reference:
J. Intraven. Nurs, 1997; 20: 201-206
Paper title:
Improved catheter care for ITU patients.
Author:
Grandi A, Cigarini, R Chiesi and S Wertzberger.
Reference:
Poster presented at the 7th European Conference on Advances in Wound Management, Milan 1997.
Paper title:
Improved catheter care in the treatment of patients with colon carcinoma. The use of OpSite* IV3000* film dressing in conjunction with continuous infusion of Topotecan.
Author:
M de Boer, A Andriessen and D den Hoed.
Reference:
6th European Conference or Advances in Wound Management proceedings, Amsterdam, Holland. 1996: abstract 276.
Paper title:
OpSite IV3000 dressing on Permcath exit sites.
Author:
C Latta and C Grant
Reference:
EDTNA-ERCA. 1996; XXII: 7-8
Paper title:
Evaluation of OpSite IV3000 versus tape and gauze dressings in the management of central venous catheters in oncology patients.
Author:
E Berggren, L Bernell and R Hast.
Reference:
5th European Conference on Advances in Wound Management proceedings, Harrogate, UK. 1995; abstract 291
Paper title:
A randomised dressing method for haemodialysis patients with permanent central venous catheters.
Author:
M Hagerstrom, K Matthleson and C Thuessen
Reference:
4th European Conference on Advances in Wound Management proceedings, Copenhagen, Denmark. 1994; abstract 197
Paper title:
A prospective randomised trial of gauze and two polyurethane dressings for site care of pulmonary artery catheters: Implications for catheter management.
Author:
D G Maki, S Stolz, S Wheeler and L Mermel
Reference:
Critical Care Medicine. 1994; 22: 1729-1737
Paper title:
Avoiding an unnecessary outcome. A comparative trial betweenOpSite IV3000 and a conventional film dressing to assess rates of catheter related sepsis.
Author:
D Keenlyside
Reference:
Professional Nurse, February 1993; 228-29
Paper title:
A comparison of two transparent film type dressings in central venous therapy.
Author:
J C Wille, A Blusse van Oud Alblas and E A P M Theweesen
Reference:
J Hospital Infection. 1993; 23: 113-121
Paper title:
A clinical evaluation of a new highly permeable film dressing OpSite IV3000, for the fixation of peripheral and central venous catheters in neonates.
Author:
A Andriessen
Reference:
University Hospital of Nijmegen AZN, Netherlands (1991). Personal Communication.
Paper title:
A prospective, randomised, three-way clinical comparison of a novel highly permeable, polyurethane dressing with 206 Swan Ganz pulmonary artery catheters: OpSite IV3000 vs. Tegaderm vs gauze and tape. ii) Nursing issues : effectiveness and tolerance as catheter dressing.
Author:
S Wheeler, S Stolz and D G Maki
Reference:
International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society and Medicine Series, London, New York 1991; 179: 67-71
Paper title:
The research and development of a new transparent film dressing for intravenous catheter care, ii) An in vivo assessment of the microbial proliferation beneath transparent film dressings.
Author:
M C Richardson
Reference:
International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 29-33
Paper title:
OpSite IV3000 ?a clinical evaluation of a new transparent film dressing for central venous catheters.
Author:
K Claeys and D Degrieck
Reference:
International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 35-40
Paper title:
OpSite IV3000 ?potential for improved quality of life for haemodialysis patients with permanent central venous catheters.
Author:
M Besley
Reference:
International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 57-59
Paper title:
OpSite IV3000 ?versus Tegaderm on peripheral venous catheters.
Author:
B Joyeux
Reference:
International Congress and Symposium Series, ‘Improving Catheter Site Care? Royal Society of Medicine Series, London, New York. 1991; 179: 53-55
Paper title:
A randomised controlled trial of the effectiveness of OpSite* Wound versus OpSite IV3000 in central line fixation.
Author:
M Neufeld
Reference:
MSc thesis, McMaster University, Canada 1991
Paper title:
Triple Lumen Study ?Abstract
Author:
D G Maki
Reference:
University of Wisconsin Hospital and Clinic, USA (1990). Clinical study. Data on file.
|